Basics of Environmental Radioactivity Measurement

How to collect and pretreat analysis samples, and how to measure environmental radioactivity and radiation are explained.

Collection and Pretreatment of Samples

Airborne dust is collected by sucking in 10,000 m3 of air over a period of 3 months using a high-volume air sampler, four times a year (April to June, July to September, October to December, and January to March).
The filter used is HE-40T, etc. The air intake opening of the high-volume air sampler is placed at a height of 1 m from the ground.

Filtration dust collector
Filtration dust collector

For fallout (rainwater, dust, etc.), a large basin (water receiving surface area: approx. 5,000 cm2) having pure water to a depth greater than 1 cm is placed at the beginning of each month (12 times a year) to receive fallout for the month.
At the end of the month, the collected fallout sample is transferred to a polyethylene bucket, and dust attached to the basin is scraped off using a rubber scraper and added to the fallout sample.
The sample is then placed in an evaporating dish or beaker in appropriate quantities, heated to evaporate and concentrate, transferred to a measurement container and further heated to dryness using an infrared lamp, and the residue is used for analysis.

Large stainless-steel basin
Large stainless-steel basin

Clean water (source water or tap water) is sampled once a year in June. Source water is collected from the center of the water intake or a source water tap of water purification plants, and tap water is collected from household taps. Fresh water such as lake water is sampled once a year, in which the surface water is collected from the center of the lake avoiding near inflows from and outflows to rivers. The collection volume is 100 L each for clean water and fresh water.
The sample is then placed in an evaporating dish or beaker in appropriate quantities, heated to evaporate and concentrate, transferred to a measurement container and further heated to dryness using an infrared lamp, and the residue is used for analysis.

Collecting tap water
Collecting tap water

Soil is collected once a year, around the end of the rainy season. The sampling location is to be an undisturbed section in a relatively large flat area that represents the nearby area. A soil sampler with an inner diameter of 5-8 cm is hammered into the ground surface to first collect 2-4 kg of the soil in the surface layer (0-5 cm) and then 6-12 kg of soil in the deeper layer (5-20 cm).
The collected samples are fully dried using a drying oven controlled at a temperature of about 105°C, and then crushed and used for analysis.

Collecting soil
Collecting soil

Sea sediment is collected once a year (in July or August), at a location with a water depth of more than 1 m at low tide and with little movement of sea sediment, using an Ekman-Birge or plane type mud collector. The amount to collect is 4 kg.
The collected samples are treated by leaving them to stand and removing the supernatant or filtering using a large Buchner funnel, spread on an enamel or stainless steel vat, fully dried using a drying oven controlled at a temperature of about 105°C, and then crushed and used for analysis.

Mud collector
Mud collector

White rice is obtained once a year, during the harvest season. The collected amount is about 3 kg, and only those with identifiable production regions are collected.

Vegetables are obtained once a year, during the harvest season. The collected amount is about 4 kg, and only those with identifiable production regions are collected. Parts usually not consumed (e.g., roots) and rotten sections are not included in the sample.
The sample is placed in a ceramic evaporating dish, either slowly carbonized using a gas burner or electric heater, or, dried using a drying oven, then placed in an electric furnace and incinerated at a temperature of 450°C for about 24 hours, and used for analysis.

Tea leaves are obtained once a year, during the first tea picking season. The collected amount is about 500 g, and unprocessed or processed tea with known production regions and collecting periods are obtained from a production plant, etc.
The sample is placed in a ceramic evaporating dish, either slowly carbonized using a gas burner or electric heater, or, dried using a drying oven, then placed in an electric furnace and incinerated at a temperature of 450°C for about 24 hours, and used for analysis.

Milk is obtained once a year, in June. The collected amount is about 3 kg, and domestically produced milk with identifiable production regions is collected.

Sea water is collected once a year (in July or August), avoiding areas into which river water flows. Approximately 40 L of sea water is collected from the sea surface using a polyethylene bucket, and placed in a polyethylene container.

Aquatic products are obtained once a year, taking into account their seasons. The type and sampling location of aquatic products are selected from the viewpoint of the appropriateness to be surveyed, such as the importance in terms of fisheries business (e.g., large catch) and the length of stay in the relevant waters (fishing grounds), and samples with identified collected waters are acquired. The collected amount is about 4 kg for fishes, 4-5 kg for shellfishes, and 2-3 kg for algae.
Obtained samples are first washed with water, dried using filter paper, etc., and pretreated (e.g., deboning and gutting for large fish (small fish is used as is), removing shells from shellfish, and removing root from algae).
Pretreated samples are placed in a ceramic evaporating dish, dried by heating for a long period of time using a gas burner or electric heater or by using a drying oven, incinerated in an electric furnace at a temperature of about 450°C for about 24 hours, and used for analysis.

Pretreating fish
Pretreating fish

Daily food is collected twice a year, in June and in November and December. One serving of normal meals (breakfast, lunch, dinner and snacks) for one day is gathered in large polyethylene jars from five households. Parts not consumed, such as fish bones and soy pods, are removed from the collected samples. Since daily food includes drinking water and other beverages, it is heated to remove moisture. The samples are further dried in a drying oven controlled at a temperature of 105°C, incinerated in an electric oven (450°C, about 24 hours), and the incineration residue is used for analysis.

Fixed time rainfall is to collect rain that has fallen in the preceding 24 hours at a fixed time (usually 9:00 am) every day and to measure the average radioactivity concentration. Samples are collected using a 70A-H radioactive precipitation collector or other similar equipment. Collected samples are mixed well, and then the volume is measured using a graduated cylinder. When the collected volume is 100 ml or less, the entire amount is used for analysis. When the collected volume is more than 100 ml, 100 ml is separated and used for analysis.
The sample is placed in an evaporating dish or beaker, evaporated to concentrate, heated to dryness using an electric heater or infrared lamp, and the residue is measured using a low-background beta counter.

Collection and pretreatment of fixed time rainfall

Environmental Radioactivity Analysis and Environmental Radiation Measurement

The analysis sample is decomposed using nitric acid, etc., to make into a solution. Carbonate precipitate (which contains Sr-90) is formed to separate Sr-90 from Cs-137. Sr-90 contained in the precipitate is separated from other metals such as calcium using the ion exchange resin method. At the time of radioactivity measurement, Y-90 generated from Sr-90 is separated and refined, and the radioactivity of Y-90 is measured using a low-background beta counter.

Radiochemical analysis of Sr-90
Radiochemical analysis of Sr-90

The analysis sample is decomposed using nitric acid, etc., to make into a solution, and carbonate precipitate is formed. The precipitate is used for the analysis of Sr-90. Cs-137 in the supernatant is adsorbed to ammonium phosphomolybdate, and separated and refined using the ion exchange resin method. Precipitate of cesium chloroplatinate is formed, and its radioactivity is measured using a low-background beta counter.

Radiochemical analysis of Cs-137
Radiochemical analysis of Cs-137

Air radiation dose rates are continuously measured using a NaI(Tl) scintillation monitor. A radiation detector is installed at a relatively high place (e.g., rooftop), or on flat grassland not surrounded by tall buildings. For the air radiation dose rates, the daily maximum, minimum, and average are derived.

Air absorbed dose rates (μGy/h) are measured using NaI(Tl) scintillation survey meters (portable simple measurement equipment). The radiation detector part is held in a horizontal orientation at a height of 1 m from the ground surface, measured values are read several times at an interval of 10-30 seconds, and an average is derived from the readings.

Air radiation dose rate measurement(measurement using a survey meter)
Air radiation dose rate measurement
(measurement using a survey meter)

Radon concentration measurement equipment is placed at a measuring position for three months. Airborne radon (Rn-222) that entered into the measurement equipment decays and releases α-rays, and the α-rays leave traces of their flight (extremely minute scar-like traces; called α-track) on a polycarbonate measurement film. The tracks are enlarged by chemical treatment, the number of the tracks is counted under observation of an optical microscope, and the radon concentration is derived.

Radon concentration measurement equipment
Radon concentration measurement equipment